NPSH Adjustment Table

The NPSH (net positive suction head) adjustment tables contain corrections to the calculated NPSH which are dependent on rules defined in the table. The table offers flexibility in defining rule options which the NPSH corrections are based and provides selection options in defining the appropriate adjustment type and how their applied.

To enter NPSH corrections:

Note: A new table will be placed in the NPSH adjustment folder. Repeat steps 2 and 3 to create as many tables necessary.

  1. Open the NPSH adjustment folder from the navigation tree.

  2. Select (left click) a NPSH adjustment table to edit.

  3. The data manager window will display the NPSH adjustment table.

  4. Defined the adjustment type and how to apply.

  5. Enter a row rule.

  6. Enter a column rule or rules.

  7. Insert the numbers of columns needed to populate your data.

  8. Select or manually enter rule criteria for the columns.

  9. Enter data in the appropriate column-row cell relationship. See the below examples.

Important : Remember to assign the correct units of measure before entering data.