XML Export Warnings
Ref |
Error Log Message |
Cause |
Location |
1 |
WARNING: The maximum impeller diameter for curve number <curve number> does not have any NPSH data. |
No NPSH data was defined in the max diameter for this curve. |
|
2 |
Warning: NPSH start flow not defined for Curve # <curve number>, Diameter # <dia>. |
NPSH start flow is zero for the specified diameter. |
|
3 |
WARNING: The MCSF at minimum diameter is greater than the MCSF at maximum diameter for curve number: <curve number> |
The MCSF is not correct for the specified curve. |
|
4 |
WARNING: In the General Curve Table, the head margin for fixed diameter is less than or = 0, for Curve Number <curve number>. Selections will not be made for head values below the fixed diameter. |
The head margin for fixed diameter may not be correct for the specified curve. |
|
5 |
WARNING: You have populated motor rating values in both the 'Fixed motor power' field in the General Curve table and the 'Motor rating min' or 'Motor rating max' fields in the Impeller table for curve number <curve number>. Results will be unpredictable in the Selector. Please choose one approach, not both. |
Both "Fixed motor power" and the "Motor Rating" fields are in use. It is recommended that only one feature be used. |
General Curve Table, Impeller Diameter Table
|
6 |
Warning: Greater than or equal to (>=) not fully supported by selector. Recommend making changes to Compatiblity Rule: <rule> |
In rules that govern data tables, the ">=" operand is not supported. Instead, have separate "=" and ">" columns. |
|
7 |
WARNING: The Enable? field for Performance Option Default ID <ID> is unchecked. This Default will not be deployed. |
Defaults need to be enabled, otherwise they will be ignored. |
|
8 |
WARNING: The Enable? field for Performance Option Category ID <ID> is unchecked. This Category (and everything below it) will not be deployed. |
In order to be deployed for use, categories must be enabled. |
|
9 |
WARNING: Max Solids diameter limit for product line <product line> is zero. This product line will not be shown if a solids diameter is defined in the Selector. |
Max solids diameter limit was not defined. |
|
10 |
WARNING: Pump <pump size>, which belongs to a product line with fixed first stages, does not have an 'alternate first stage' specified. |
The stage mixing table entry for this pump may not be filled out correctly. |
|
11 |
WARNING: Mixed stage data exists but is not enabled in the General Product Line Table. Data will not be deployed. |
Mixed stage data must be properly set on the product line level in order to be deployed. |
|
12 |
WARNING: Working pressure data has not be defined for Option ID <ID>. |
This option is not linked to a working pressure table. |
|
13 |
WARNING: <Engineering Data Table> data exists, but is not enabled. Data will not be deployed. |
Engineering data tables need to be enabled in the General Product Line Table in order to be deployed. |
|
14 |
WARNING: Curve number <curve number> related to pump size <pump size> does not exist in any curve families. |
The curve number assigned to this pump size is not valid. |
|
15 |
WARNING: Motor supplierID <ID> related to pump size <pump size> does not exist in any motor families. |
The motor assigned to this pump size is not valid. |
Pump Size and Motor Relation |
16 |
WARNING: Multiple curves have been detected for pump size <pump size>. Multiple curves are only permitted for ITO pump sizes providing the curves are at different poles or Hz, with appropriate speed limits, such that only ONE of the curves is compatible for a particular speed. |
This pump size is from a product line using ITO stage mixing. The curves specified for this pump may not be correct. |
|
17 |
WARNING: Solids diameter limit for pump size <pump size> is zero. This pump will not be selected if a solids diameter is defined in the Selector. |
Max solids diameter limit was not defined. |
|
18 |
WARNING: Subcategory <subcat> has default(s) defined, but is not auto-upgrade enabled. These default(s) will only apply the first time the Selector needs to determine a compatible option, and from then on, they will be ignored. |
Defaults are specified, and auto-upgrade is not enabled. The Selector may not behave as desired. |
|
19 |
WARNING: You have populated motor rating values in both the 'Fixed motor power' field in the General Curve table and the 'Motor rating min' or 'Motor rating max' fields in the Impeller table for curve number <curveNumber>. Results will be unpredictable in the Selector. Please choose one approach, not both |
These two motor power features can not be used at the same time. Disable one or both of them in order to deploy successfully. |