XML Export Errors

 

Ref

Error Log Message

Cause

Location

1

ERROR: In the Performance Options Table under subcategory SC-MTL, a pressure ID does not exist for <option>.

A pressure table ID has not been defined for a material option ID.

Product Line Options Table

2

ERROR: <Subcategory> doesn't have any options defined. Either create some, or detele this subcategory.

A subcategory exists that has no options in it.

Product Line Options Table

3

ERROR:  The "Enable?" field for Performance Option Subcategory <subcat> is unchecked.  This Subcategory (and everything below it) will not be deployed.

A subcategory exists that is not enabled.

Product Line Options Table

4

ERROR:  The poles and/or Hz specified for curve number  <curve number> does not correlate with the curve nominal speed.

The poles, Hz, or nominal speed settings are incorrect for the specified curve.

General Curve Table

5

ERROR: The margin of (speed, data * #poles) compared to (Speed, nominal * # poles) is greater than 25% for Curve Number <curve number>. Data will not be deployed.

The nominal speed or speed, data settings are incorrect for the specified curve number.

General Curve Table

6

ERROR: Speed minimum is greater than (>) or equal (=) to speed nominal for Curve# <curve number>. Data will not be deployed.

The nominal speed or minimum speed settings are incorrect for the specified curve number.

General Curve Table

7

ERROR: The minimum speed is greater than the maximum speed for Curve # <curve number>.

The maximum speed or minimum speed settings are incorrect for the specified curve number.

General Curve Table

8

ERROR: In the General Curve Table, the trim/pitch affinity exponent for head for Curve Number <curve number> is less than one. This is not acceptable.

The speed affinity exponent for head for that curve is incorrect.

General Curve Table

9

ERROR: In the General Curve Table, the trim/pitch affinity exponent for flow for Curve Number <curve number> is less than one. This is not acceptable.

The speed affinity exponent for flow for that curve is incorrect.

General Curve Table

10

ERROR: The minimum speed is greater than the maximum speed for pump size <pump size>.

The maximum speed or minimum speed settings are incorrect for the specified pump size.

Pump Size Table

11

ERROR: In the Pump Size Table, no Supplier ID exists for pump size and type <pump size>.

The Supplier ID cell was left blank for that pump size.

Pump Size Table

12

ERROR: Enable button is checked in the General Product Line table, for product line <product line>. But not all data has been defined or no data columns exist in the Engineering Data  table <table name>.

An engineering data table is enabled, but is not completed correctly.

General Product Line Table, Engineering Data

13

ERROR:  In the Performance Option Subcategory Table for product line <product line>, a subcategory ID, SC-Mtl doesn't exist.

SC-Mtl was not created for the specified product line. This is a requirement.

Product Line Options Subcategory Table

14

ERROR - Working pressure limit table index number of <#> for material <material ID> is invalid.  This must be an integer.

The pressure table ID for the specified material is incorrect.

Product Line Options Table

15

ERROR: Duplicate Category ID: <ID> is found. Duplication has been removed from xml file.

More than one category has the same ID. All categories under one product line must be unique.

Product Line Options Category Table

16

ERROR: Enable button is checked in the General Product Line table, for product line <product line>. But not all data has been defined in the Mixed stage compatibility table.

Mixed stage compatibility table is not filled out correctly, or stage mix setting is incorrect.

Mixed Stage Compatibility Table

17

ERROR: Pump <pump size> in the mixed stage compatibility table has a Dynamic first stage listed before the FIRST Fixed first stage.  This is not supported.

In the Mixed stage compatibility table, fixed first stages should come first.

Mixed Stage Compatibility Table

18

ERROR: Pump <pump size>, which belongs to a product line with fixed first stages, must have at least a minimum of two stages.

At least two stages are needed for a pump using the fixed first stage feature. Check the stage settings.

Pump Size Table

19

ERROR: The SupplierID <ID> for pump size <pump size> under Product line <product line> is not unique.

All Supplier ID's must be unique.

Pump Size Table

20

ERROR:  Product line <product line> has no compatibility data defined for Construction Specifications.

The product line compatibility table is not complete.

Product Line Compatibility

21

ERROR:  Product line <product line> has no compatibility data defined for Product Classification.

The product line compatibility table is not complete.

Product Line Compatibility

22

ERROR:  Product line <product line> has no compatibility data defined for Industry.

The product line compatibility table is not complete.

Product Line Compatibility

23

ERROR:  Product line <product line> has no compatibility data defined for Orientation.

The product line compatibility table is not complete.

Product Line Compatibility

24

Error: The head convergence criteria is less than or equal to zero for Product Line <product line>. Data will not be deployed.

The head convergence criteria for the specified product line is incorrect.

General Product Line Table

25

ERROR: In the General Product Line Table, no product line Supplier ID exists for product line <product line>.

Supplier ID was not filled in for the specified product line.

General Product Line Table

26

ERROR:  The data <data> contained in the 'Auto-pick product lines' for product line <product line> is not well formed.  It must be a list of product line supplier ID's delimited with semicolons.

The "Auto-pick product lines" cell is not being used correctly.

General Product Line Table

27

ERROR: Duplicate Subcategory ID: <ID>  is found. Duplication has been removed from xml file.

All Subcategories in a product line must have a unique ID.

Product Line Options Category Table

28

Error: Volumetric efficiency is zero for Curve # <curve number>. This must be fixed otherwise selection errors will result.

Efficiency data was not correctly provided for the specified curve.

Point Data Tables

29

ERROR: No organization name defined.

Every database must have an organization name.

Organization Name

30

ERROR: No motors are defined for Motor Family <motor family>. Data will not be deployed.

The specified motor family has no data.

General Motor Table

31

ERROR: In the Motor Curve Table, the motor supplierID <supplier ID> under Motor Family <motor family> is not unique. Identical motor supplierID found in Motor Family <motor family>.

Supplier ID must be unique.

General Motor Table

32

Error: Limit of 5 exceded for combined "On curve" and "Slope=0" per curve for Motor <motor ID>, curve type = <curve type>.

Too many "On curve" and/or "Slope=0" boxes have been checked in the specified motor curve.

Motor Point Data Tables

33

Error: Minimum number of data points not met for Motor <ID>, curve type = <curve type>.

There are not enough data points in the specified motor curve.

Motor Point Data Tables

34

ERROR: Motor <ID> does not have any point data for Power Factor curve.

Data is missing from specified motor curve.

Motor Point Data Tables

35

ERROR: Motor <ID> does not have any point data for Current curve.

Data is missing from specified motor curve.

Motor Point Data Tables

36

ERROR: Motor <ID> does not have any point data for Speed curve.

Data is missing from specified motor curve.

Motor Point Data Tables

37

ERROR:  Not all rules have been defined in Engineering Data table <table name>.

There is a blank rule in the specified table.

Engineering Data

38

ERROR:  Not all data has been defined in Engineering Data table <table name>.

There is data missing in the specified table.

Engineering Data

39

ERROR: Impeller Diameter <dia> Shutoff power enable? field checked, but the shutoff power value is 0. Shutoff power enabled will be set to false.

Shutoff power was enabled, but not specified.

Impeller Diameter Table

40

ERROR: In the General Curve Table, the curve number <curve number> under Curve Family <curve family> is not unique, identical curve number found in Curve Family <curve family>.

All curve numbers must be unique.

General Curve Table

41

ERROR: In the Impeller Diameter Table, the impeller diameters are not unique for curve number <curve number>, data will not be deployed.

Duplicate diameters were found in the specified curve.

Impeller Diameter Table

42

ERROR: No impeller diameters are defined for Curve Numer <curve number>. Data will not be deployed.

The specified curve has no impeller data.

Impeller Diameter Table

43

Error: Invalid Stop Flow value for Curve # <curve number>. This value is expected to be greater than 100.

Stop Flow for the specified curve is not filled out correctly.

Impeller Diameter Table

44

ERROR:  The data <data> contained in the 'ISO efficiency values' for Curve # <curve number> is not well formed.  It must be a list of values between 0 and 100 and be delimited with colons.

The "ISO efficiency values" cell for the specified curve is not filled out correctly.

General Curve Table

45

ERROR: Zero flow data point doesn't exist for <curve type> for Curve # <curve number>, Diameter # <dia>.

A data point for flow = 0 is needed for all curves.

Point Data Tables

46

ERROR: The power is 0 for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>, for a flow other than 0. Data will not be deployed.

The specified data point is causing the calculated power to equal zero. Verify the data for this curve.

Point Data Tables

47

ERROR: The head is set to 0 for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>. Data will not be deployed.

Head data is typically greater than zero. Verify the head data for this curve.

Point Data Tables

48

ERROR: Curve number <curve number>, Diameter # <dia> does not have any HEAD data.

Head data is missing from this curve.

Point Data Tables

49

Error: The efficiency is 0  for Curve #  <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>, for a flow other than 0. Data will not be deployed.

Efficiency data is always positive above flow = 0. Verify the efficiency data for this curve.

Point Data Tables

50

Error: Invalid value for efficiency for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>.

Efficiency data was not entered correctly for the specified curve.

Point Data Tables

51

Error: Limit of 5 exceded for combined "On curve" and "Slope=0" per curve for Curve # <curve number>, Diameter # <dia>, type = <curve type>.

Too many "On curve" and/or "Slope=0" boxes have been checked in the specified curve.

Point Data Tables

52

Error: Minimum number of data points not met for Curve # <curve number>, Diameter # <dia>, type = <curve type>.

There are not enough data points in the specified curve.

Point Data Tables

53

Error: The maximum number of stages for pump size <pump size> is less than the minimum number of stages.

Either the minimum or maximum stages for this pump size is not correct.

Pump Size Table

 

54

Error:  The data contained in the 'Allowable stages' for pump size <pump size> is not well formed.  It must be a list of integers delimited with colons.

The "Allowable Stages" cell for the specified pump size is not filled out correctly.

Pump Size Table