XML Export Errors
Ref |
Error Log Message |
Cause |
Location |
1 |
ERROR: In the Performance Options Table under subcategory SC-MTL, a pressure ID does not exist for <option>. |
A pressure table ID has not been defined for a material option ID. |
|
2 |
ERROR: <Subcategory> doesn't have any options defined. Either create some, or detele this subcategory. |
A subcategory exists that has no options in it. |
|
3 |
ERROR: The "Enable?" field for Performance Option Subcategory <subcat> is unchecked. This Subcategory (and everything below it) will not be deployed. |
A subcategory exists that is not enabled. |
|
4 |
ERROR: The poles and/or Hz specified for curve number <curve number> does not correlate with the curve nominal speed. |
The poles, Hz, or nominal speed settings are incorrect for the specified curve. |
|
5 |
ERROR: The margin of (speed, data * #poles) compared to (Speed, nominal * # poles) is greater than 25% for Curve Number <curve number>. Data will not be deployed. |
The nominal speed or speed, data settings are incorrect for the specified curve number. |
|
6 |
ERROR: Speed minimum is greater than (>) or equal (=) to speed nominal for Curve# <curve number>. Data will not be deployed. |
The nominal speed or minimum speed settings are incorrect for the specified curve number. |
|
7 |
ERROR: The minimum speed is greater than the maximum speed for Curve # <curve number>. |
The maximum speed or minimum speed settings are incorrect for the specified curve number. |
|
8 |
ERROR: In the General Curve Table, the trim/pitch affinity exponent for head for Curve Number <curve number> is less than one. This is not acceptable. |
The speed affinity exponent for head for that curve is incorrect. |
|
9 |
ERROR: In the General Curve Table, the trim/pitch affinity exponent for flow for Curve Number <curve number> is less than one. This is not acceptable. |
The speed affinity exponent for flow for that curve is incorrect. |
|
10 |
ERROR: The minimum speed is greater than the maximum speed for pump size <pump size>. |
The maximum speed or minimum speed settings are incorrect for the specified pump size. |
|
11 |
ERROR: In the Pump Size Table, no Supplier ID exists for pump size and type <pump size>. |
The Supplier ID cell was left blank for that pump size. |
|
12 |
ERROR: Enable button is checked in the General Product Line table, for product line <product line>. But not all data has been defined or no data columns exist in the Engineering Data table <table name>. |
An engineering data table is enabled, but is not completed correctly. |
|
13 |
ERROR: In the Performance Option Subcategory Table for product line <product line>, a subcategory ID, SC-Mtl doesn't exist. |
SC-Mtl was not created for the specified product line. This is a requirement. |
|
14 |
ERROR - Working pressure limit table index number of <#> for material <material ID> is invalid. This must be an integer. |
The pressure table ID for the specified material is incorrect. |
|
15 |
ERROR: Duplicate Category ID: <ID> is found. Duplication has been removed from xml file. |
More than one category has the same ID. All categories under one product line must be unique. |
|
16 |
ERROR: Enable button is checked in the General Product Line table, for product line <product line>. But not all data has been defined in the Mixed stage compatibility table. |
Mixed stage compatibility table is not filled out correctly, or stage mix setting is incorrect. |
|
17 |
ERROR: Pump <pump size> in the mixed stage compatibility table has a Dynamic first stage listed before the FIRST Fixed first stage. This is not supported. |
In the Mixed stage compatibility table, fixed first stages should come first. |
|
18 |
ERROR: Pump <pump size>, which belongs to a product line with fixed first stages, must have at least a minimum of two stages. |
At least two stages are needed for a pump using the fixed first stage feature. Check the stage settings. |
|
19 |
ERROR: The SupplierID <ID> for pump size <pump size> under Product line <product line> is not unique. |
All Supplier ID's must be unique. |
|
20 |
ERROR: Product line <product line> has no compatibility data defined for Construction Specifications. |
The product line compatibility table is not complete. |
|
21 |
ERROR: Product line <product line> has no compatibility data defined for Product Classification. |
The product line compatibility table is not complete. |
|
22 |
ERROR: Product line <product line> has no compatibility data defined for Industry. |
The product line compatibility table is not complete. |
|
23 |
ERROR: Product line <product line> has no compatibility data defined for Orientation. |
The product line compatibility table is not complete. |
|
24 |
Error: The head convergence criteria is less than or equal to zero for Product Line <product line>. Data will not be deployed. |
The head convergence criteria for the specified product line is incorrect. |
|
25 |
ERROR: In the General Product Line Table, no product line Supplier ID exists for product line <product line>. |
Supplier ID was not filled in for the specified product line. |
|
26 |
ERROR: The data <data> contained in the 'Auto-pick product lines' for product line <product line> is not well formed. It must be a list of product line supplier ID's delimited with semicolons. |
The "Auto-pick product lines" cell is not being used correctly. |
|
27 |
ERROR: Duplicate Subcategory ID: <ID> is found. Duplication has been removed from xml file. |
All Subcategories in a product line must have a unique ID. |
|
28 |
Error: Volumetric efficiency is zero for Curve # <curve number>. This must be fixed otherwise selection errors will result. |
Efficiency data was not correctly provided for the specified curve. |
|
29 |
ERROR: No organization name defined. |
Every database must have an organization name. |
|
30 |
ERROR: No motors are defined for Motor Family <motor family>. Data will not be deployed. |
The specified motor family has no data. |
General Motor Table |
31 |
ERROR: In the Motor Curve Table, the motor supplierID <supplier ID> under Motor Family <motor family> is not unique. Identical motor supplierID found in Motor Family <motor family>. |
Supplier ID must be unique. |
General Motor Table |
32 |
Error: Limit of 5 exceded for combined "On curve" and "Slope=0" per curve for Motor <motor ID>, curve type = <curve type>. |
Too many "On curve" and/or "Slope=0" boxes have been checked in the specified motor curve. |
Motor Point Data Tables |
33 |
Error: Minimum number of data points not met for Motor <ID>, curve type = <curve type>. |
There are not enough data points in the specified motor curve. |
Motor Point Data Tables |
34 |
ERROR: Motor <ID> does not have any point data for Power Factor curve. |
Data is missing from specified motor curve. |
Motor Point Data Tables |
35 |
ERROR: Motor <ID> does not have any point data for Current curve. |
Data is missing from specified motor curve. |
Motor Point Data Tables |
36 |
ERROR: Motor <ID> does not have any point data for Speed curve. |
Data is missing from specified motor curve. |
Motor Point Data Tables |
37 |
ERROR: Not all rules have been defined in Engineering Data table <table name>. |
There is a blank rule in the specified table. |
|
38 |
ERROR: Not all data has been defined in Engineering Data table <table name>. |
There is data missing in the specified table. |
|
39 |
ERROR: Impeller Diameter <dia> Shutoff power enable? field checked, but the shutoff power value is 0. Shutoff power enabled will be set to false. |
Shutoff power was enabled, but not specified. |
|
40 |
ERROR: In the General Curve Table, the curve number <curve number> under Curve Family <curve family> is not unique, identical curve number found in Curve Family <curve family>. |
All curve numbers must be unique. |
|
41 |
ERROR: In the Impeller Diameter Table, the impeller diameters are not unique for curve number <curve number>, data will not be deployed. |
Duplicate diameters were found in the specified curve. |
|
42 |
ERROR: No impeller diameters are defined for Curve Numer <curve number>. Data will not be deployed. |
The specified curve has no impeller data. |
|
43 |
Error: Invalid Stop Flow value for Curve # <curve number>. This value is expected to be greater than 100. |
Stop Flow for the specified curve is not filled out correctly. |
|
44 |
ERROR: The data <data> contained in the 'ISO efficiency values' for Curve # <curve number> is not well formed. It must be a list of values between 0 and 100 and be delimited with colons. |
The "ISO efficiency values" cell for the specified curve is not filled out correctly. |
|
45 |
ERROR: Zero flow data point doesn't exist for <curve type> for Curve # <curve number>, Diameter # <dia>. |
A data point for flow = 0 is needed for all curves. |
|
46 |
ERROR: The power is 0 for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>, for a flow other than 0. Data will not be deployed. |
The specified data point is causing the calculated power to equal zero. Verify the data for this curve. |
|
47 |
ERROR: The head is set to 0 for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>. Data will not be deployed. |
Head data is typically greater than zero. Verify the head data for this curve. |
|
48 |
ERROR: Curve number <curve number>, Diameter # <dia> does not have any HEAD data. |
Head data is missing from this curve. |
|
49 |
Error: The efficiency is 0 for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>, for a flow other than 0. Data will not be deployed. |
Efficiency data is always positive above flow = 0. Verify the efficiency data for this curve. |
|
50 |
Error: Invalid value for efficiency for Curve # <curve number>, Diameter # <dia>, type = <curve type>, DataPoint # = <x, y>. |
Efficiency data was not entered correctly for the specified curve. |
|
51 |
Error: Limit of 5 exceded for combined "On curve" and "Slope=0" per curve for Curve # <curve number>, Diameter # <dia>, type = <curve type>. |
Too many "On curve" and/or "Slope=0" boxes have been checked in the specified curve. |
|
52 |
Error: Minimum number of data points not met for Curve # <curve number>, Diameter # <dia>, type = <curve type>. |
There are not enough data points in the specified curve. |
|
53 |
Error: The maximum number of stages for pump size <pump size> is less than the minimum number of stages. |
Either the minimum or maximum stages for this pump size is not correct. |
|
54 |
Error: The data contained in the 'Allowable stages' for pump size <pump size> is not well formed. It must be a list of integers delimited with colons. |
The "Allowable Stages" cell for the specified pump size is not filled out correctly. |